MNX 系列 50-75W 工业X射线发生器 (Featured)

MNX 系列

  • 50kV,50 或 75 W(最大值)
  • 65kV,65 W(最大值)
  • 可调式集成灯丝电源
  • 本地和远程放射控制
  • CE 标识,UL 认证

*注意:所有规格如有变更,恕不另行通知。有关最新修订,请参阅本数据表的英文 PDF 版本


 

两年延保 CE ROHS RU 标识

斯派曼MNX系列50-75W工业X射线发生器

MNX 系列采用斯派曼特殊的高压封装和表面贴装制造技术,结合斯派曼专有的封装技术,生产出超紧凑的X 射线发生器模块。MNX 给很多著名制造商的阴极接地X 射线管供电,特征:高压输出电压从0 至50kV/65kV,电流从0 至2mA,功率限制为50W、65W 或75W。MNX 使用闭环灯丝控制电路,提供高精度调节射线束电流。对地参考,工作在0.3A 和3.5A 之间的低噪声直流灯丝电源。提供严谨性调控、高稳定性和低纹波。MNX 提供用户本地和远程模拟控制,去设置管电压、管电流和灯丝电流限制。

典型应用:

给Kevex、Oxford、RTW、Superior、Varex、Petrick、和Trufocus的阴极接地X 射线管供电。

规格

(Ref. 128023-001 REV. AE)

Input Voltage:

+24Vdc ±10%, for 50W or 75W units

+24Vdc ±1V, for 65kV @ 65W unit

Input Current:

MNX50P50: 4.0 amps, maximum

MNX50P75: 6.0 amps, maximum

MNX65P65: 5.0 amps, maximum

GB Option: 1.0 amp additional, maximum

Efficiency:

80-85%, typical

Output:

0 to 50kV at 0 to 2mA, limited to a maximum of 50 watts or 75 Watts. 0-65kV at 2mA limited to 65 Watts.

Voltage Control:

Local: Internal multi-turn potentiometer to set voltage from 0 to full output voltage.

Remote: 0 to +10Vdc proportional from 0 to full output voltage. Accuracy: ±1%. ZIN: 10Mohm.

Emission Control:<

Local: Internal potentiometer to set beam current between 0 and full output current.

Remote: 0 to +10Vdc proportional from 0 to full output current. Accuracy : ±1%. ZIN: 10Mohm. Filament limit and filament preheat control capability is also provided.

DC Filament Supply:

Current: 3.5A, adjustable limit

Voltage: 5.0 volt limit

Voltage Regulation:

Load: 0.01% of output voltage no load to full load.

Line: ±0.01% for ±10% change in input voltage.

Current Regulation:

Load: 0.01% of output current from 0 to rated voltage.

Line: ±0.01% for ±10% change in input voltage.

Ripple:

0.1% p-p of maximum rated output voltage, 50kV units (50/75W)

0.1% rms maximum rated output voltage, 65kV units (65W)

Environmental:

Operational: 0°C to +50°C

Storage: -40°C to +85°C

Humidity: 0% to 90%, non-condensing

Temperature Coefficient:

0.01% per °C, voltage and current.

Stability:

0.05% per 8 hours after 1/2 hour warm-up.

Voltage and Current Monitors:

0 to +10Vdc proportional from 0 to rated output. Accuracy ±1%.

Dimensions:

50kV Unit: 5.00”H x 2.87”W x 8”D (127.00mm x 72.90mm x 203.25mm)

65kV Unit: 5.00”H x 2.87”W x 9”D (127.00mm x 72.90mm x 228.65mm)

XCC Option: 5.00”H x 2.87”W x 9”D (50/75W units only) (127.00mm x 72.90mm x 228.65mm)

Weight:

6.5 lbs. (2.9kg)

Regulatory Approvals:

Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive. UL/CUL recognized, File E227588; MNX65P65 is not UL/CUL recognized. RoHS Compliant

OPTIONS

XCC - XRM Compatible HV Cable (50kV only)

5VPM - 0 to 5 Volt Programming and Monitor Scaling

5302 - Mammoflex HV cable for MNX

2001 - Mammoflex HV cable for MNX w/XCC option

 

J2 POWER INPUT CONNECTOR

Pin Signal Parameter
1 +24V Input +24 volts @ 5A, max.
2 24V Return (Gnd.) Power Ground

J3 FILAMENT CONNECTOR

Pin Signal Parameter
1 Filament Out 0.3A to 3.5A, 5 volt, max.
2 Filament Return Filament Ground

J4 ANALOG INTERFACE CONNECTOR MALE 15 PIN MINI "D"

Pin Signal Parameters
1 Monitor Return Signal Ground
2 Voltage Monitor 0-10 volts = 0 to full scale, Zout=1KΩ
3 Current Monitor 0-10 volts = 0 to full scale, Zout=1KΩ
4 Interlock Output Connect 12V HVON bulb to pin 15 to enable
5 +10 Volt Reference +10 Volts at 1mA, maximum
6 Filament Monitor 1 volt = 1 amp, Zout=1KΩ
7 Voltage Program Input 0-10 volts = 0 to full scale, Zin=10MΩ
8 Local Voltage Program* 0-10 volts, screwdriver adjust
9 Filament Limit Setpoint* 1 volt = 1 amp, screwdriver adjust
10 Current Program Input 0-10 volts = 0 to full scale, Zin=10MΩ
11 Local Current Program* 10 turn pot, screwdriver adjust
12 Not used (+24V Out for Interlock) (Optional Interlock configuration)
13 Not used (Interlock Coil) (Optional Interlock configuration)
14 Filament Preheat Setpoint* 1 volt = 1 amp, screwdriver adjust
15 Interlock Return Interlock Ground

 *Denotes 10 turn potentiometer located on front panel

J1 HIGH VOLTAGE OUTPUT CONNECTOR

Spellman drywell type detachable connector.

Standard: A one meter (39.4”) long polyethylene mating high
voltage cable is provided.

5302: A one meter (39.4”) long Mammoflex mating high voltage
cable is provided, SHV p/n 201946-007

2001: A one meter (39.4”) long Mammoflex mating high voltage cable
is provided, compatible with the XCC Option SHV p/n 201946-002

Drywell connector depth:
voltage cable is provided.

50kV: 7.25˝

65kV: 8.25˝

XCC Option: 8.25˝

How to Order:

Sample model number:
50 Watt unit: MNX50P50
65 Watt unit: MNX65P65
75 Watt unit: MNX50P75

Options are added to the model number as follows:
MNX50P50/XCC

表和图