Spellman MPS20W DC-DC 20W 高压电源
斯派曼MPS20W 系列是一个20W 高压模块,输出电压范围从1kV 至10kV。
MPS20W 系列使用了斯派曼线性的混合拓扑技术和开关模式功率转换技术,提供低噪声具有更高效率的高性能产品设计。MPS20W 系列从紧凑的封装产生出卓越的纹波和稳定的性能规格。此外MPS20W 系列标配,用于电压编程信号的差分放大器输入,可更好地隔离外部噪音并解决任何偏移问题。另外输出电压可以通过内部的电位器预设。
通过15 针D 型连接器提供一个全功能的远程用户界面作为标准。输出电压具有电弧和短路保护,电源输入配有限流器。
斯派曼专有的高压技术与SMT 电路相结合造就了一个超紧凑并重量轻的模块,可提供正的或负的极性输出,可完美地适合OEM 应用。
典型应用:
- 光电倍增管
- 微通道板检测器
- 闪烁器
- 质谱分析
- 电子束和离子束
- 静电透镜
- 原子能仪器
- 静电印刷
规格
(Ref. 128064-001 REV. G)
Input Voltage:
+24 Vdc, ±2Vdc
Input Current:
≤ 1.5 amps
Output Voltage:
7 models available from 1kV to 10kV
Output Polarity:
Positive or negative, specify at time of order
Power:
≤ 20 watts
Voltage Regulation:
Line: ≤ 0.001% of rated output voltage over specified input voltage
Load: ≤ 0.001% of rated output voltage for full load change
Current Regulation (Vcc Option):
Line: ≤ 0.01% for 1V input voltage change under any load conditions
Load: ≤ 0.001% for 0 to full load
Ripple:
See “model selection” table
Stability:
≤ 0.01% per hour, 0.02% per 8 hours after 1.0 hour warm up period.
Temperature Coefficient:
≤ 25ppm per degree C
Environmental:
Temperature Range:
Operating: 0°C to 50°C
Storage: -35°C to 85°C
Humidity:
20% to 85% RH, non-condensing
Cooling:
Convection cooled
Dimensions:
1.31. H X 3.74. W X 5.91. D (33.5mm x 95mm x 150mm)
Weight:
1-2kV: 15.17 oz. (430g)
3-10kV: 25.76 oz. (730g)
15-20kV: 35.30 oz. (1000g)
Interface Connector:
15 pin male D connector
Output Connector:
A captive 39.4. (1 meter) long shielded HV cable is provided
Regulatory Approvals:
Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive.
MPS20W SELECTION TABLE
Model | Output Voltage | Output Current | Ripple (Vpp) |
---|---|---|---|
MPS1*20/24 | 0-1kV | 20mA | <25mV |
MPS2*20/24 | 0-2kV | 10 mA | <50mV |
MPS3*20/24 | 0-3kV | 6.67mA | <75mV |
MPS5*20/24 | 0-5kV | 4mA | <125mV |
MPS10*20/24 | 0-10kV | 2mA | <125mV |
MPS15*20/24 | 0-15kV | 1.33mA | <375mV |
MPS20*20/24 | 0-20kV | 1mA | <500mV |
*Specify “P” for positive polarity or “N” for negative polarity. Custom units available.
MPS20W ANALOG INTERFACE— 15 PIN D CONNECTOR
Pin | Signal | Signal Parameters |
---|---|---|
1 | Power/Signal Ground | Ground |
2 | +24Vdc Input | +24Vdc @ 1.5 amp maximum |
3 | Voltage Monitor Output | 0 to 10Vdc=0 to 100% Rated Output, Zout =2.2kΩ |
4 | Local Programming Potentiometer Wiper Output | Potentiometer connected to +10Vdc and Ground, 0 to 10Vdc adjustable wiper output provided |
5 | Voltage Program Input | 0 to 10Vdc=0 to 100% Rated Output, Zin=10MΩ |
6 | Voltage Program Differential Amplifier Output | 0 to 10Vdc=0 to 100% Rated Output, Zout =2.2kΩ |
7 | Voltage Program Differential Amplifier Input—Positive | 0 to 10Vdc differential between pin 7 and pin 9 = 0 to 100% of rated output, diode clamped to ground, Zin =38kΩ |
8 | Current Monitor Output | 0 to 10Vdc = 0 to 100% Rated Output, Zout =2.2kΩ |
9 | Voltage Program Differential Amplifier Input—Negative | 0 to 10Vdc differential between pin 7 and pin 9 = 0 to 100% of Rated Output, diode clamped to ground, Zin =38kΩ |
10 | No Connection | No Connection |
11 | Current Program Input | Standard: Internally connected to provide 110% fixed current limit VCC Option: 0 to 10Vdc=0 to 100% Rated Output, Zin=1MΩ |
12 | Enable Input | Low = Enable, TTL, CMOS, Open Collector Compliant |
13 | Internal Connection | No Connection |
14 | No Connection | No Connection |
15 | Analog Signal Ground | Analog Signal Ground |
表和图
DIMENSIONS: in.[mm]
1-10kV Unit
FRONT VIEW
SIDE VIEW
BOTTOM VIEW
15-20kV Unit
FRONT VIEW
SIDE VIEW
BOTTOM VIEW
Frequently Asked Questions
What Is a Safe Level of High Voltage?
Where Can I Obtain Information on High Voltage Safety Practices?
What Kind of High Voltage Connector Do You Use on Your Supplies?
What Do You Mean That the Output Side of the High Voltage Cable on Most Standard Products Is “Unterminated”?
How Should I Ground Your Supply?
Why Is Arcing an Issue for a High Voltage Power Supply?