XRB100 Monoblock® 工业X射线发生器 (featured)

XRB100N100 Monoblock® 工业X射线发生器

  • 集成高压电源,灯丝电源,X 射线管,电子束端口和控制电子设备
  • 紧凑,轻便
  • 通用输入,功率因数校正,内置 EMI 滤波器
  • 可以安装在任何物理方向
  • 模拟控制接口和标准 RS-232 数字接口

*注意:所有规格如有变更,恕不另行通知。有关最新修订,请参阅本数据表的英文 PDF 版本

100kV,100W X 射线源

  斯派曼 XRB100N100 系列 Monoblock® X 射线源专为 OEM 应用而设计。输出电压为 100kV,功率为 100W,为内部 X 射线管供电。产品具有通用输入,小封装尺寸,标准模拟和 RS232 数字接口等特点,使得此 Monoblock® 能更简单集成到您的 X 射线系统中。专有的发射控制电路提供了卓越的 X 射线管电流管理,同时具有出色的稳定性能。

典型应用:

  • X 射线扫描:食品检验、液位确认和安防应用

规格

(Ref. 128072-001 REV. L)

X-Ray Characteristics:

Tube Type: Stationary anode, tungsten target

Focal Spot: 0.5mm (IEC 336)

Beam Filter: Lexan: 3.2mm

Oil: 10mm ±0.1mm

Glass: 1.8mm max

Beam Geometry: Symmetrical fan 74° x 10° ±1°

Input Voltage:

Power factor corrected input 0.98, 100-240Vac ±10% 50/60Hz, 2A, maximum

X-Ray Tube Voltage:

Nominal X-Ray tube voltage is adjustable between 40kV to 100kV

X-Ray Tube Current: 

100uA to 1mA over specified tube voltage range

X-Ray Tube Power:

100W, maximum continuous

Voltage Regulation:

Line: ±0.1% of maximum output voltage over a ±10% change of nominal input line voltage 

Load: ±0.1% of maximum rated voltage for 100uA to 1mA load change

Voltage Accuracy:

Voltage measured across the X-Ray tube is within ±2% of the programmed value

Voltage Risetime:

Ramp time shall be 1 second from 10% to 90% of maximum rated output voltage

Voltage Overshoot:

5% of maximum voltage, to return within 2.5% of maximum voltage in less than 50ms

Voltage Ripple:

0.5% peak to peak of maximum voltage for frequencies ≤ 1kHz

Emission Current Parameters Current Regulation:

Line:  ±0.5% of rated output current over a ±10% change of nominal input line voltage  

Load:  ±0.5% of rated output current for a change from 50% to 100% of rated output voltage

Current Accuracy:

Current measured through the X-Ray tube is within ±1% of the programmed value

Current Risetime:

Ramp time shall be 1 second from 10% to 90% of maximum rated current

Arc Intervention:

3 arcs in 10 seconds with a 200ms quench = Shutdown

Filament Configuration:

Internal high frequency AC filament drive with closed loop filament emission control

Analog Interface:

Ground referenced 0 to 9Vdc for all programming and monitoring signals. Relay contacts and open collector signals for other signals. See analog interface connector pin out table.

Digital Interface:

Jumpers are needed to be configured and the digital interface cable installed to enable the RS-232 interface.

Control Software:

A demo GUI is available for engineering evaluations.

Interlock/Signals:

A hardware interlock functions in both analog and digital programming modes. The hardware X-Ray Enable signal only functions in analog programming mode.

Operating Temperature:

0°C to +40°C

Storage Temperature:

-40°C to +70°C

Humidity:

10% to 95% relative humidity, non-condensing

Cooling:

Forced air and natural convection augmented by customer provided external cooling fan to maintain oil temperature below 55°C.

Input Line Connector:

3 pin, Phoenix Contact 1829167, SHV part number 105725-219. Mating connector Phoenix Contact #1805990, SHV part number 105808-475 provided with unit.

Analog Interface Connector: 

15 pin D connector, male

Digital Interface Connector:

9 pin D connector, female

Grounding Point:

M4 ground stud provided on chassis

Dimensions:

See page 3 of 3

Weight:

55lbs (25kg)

Orientation:

Can be mounted in any orientation.

X-Ray Leakage:

Not to be greater than 0.5mR/hr at 5cm outside the external surface.

AC LINE POWER CONNECTOR— J1 THREE POSITION PHOENIX CONTACT

Pin Signal
1 Earth Ground
2 Line
3 Neutral

Mating connector provided with unit

RS-232 DIGITAL INTERFACE— J3 9 PIN FEMALE D CONNECTOR

Pin Signal Parameters
1 N/C No Connection
2 TD Transmit Data
3 RD Receive Data
4 N/C No Connection
5 SGND Signal Ground
6 NC No Connection
7 NC No Connection
8 NC No Connection
9 NC No Connection

XRB ANALOGINTERFACE— J2 15 PIN MALE D CONNECTOR

Pin Signal Parameters
1 Power Supply Fault Output
PARAMETERS
Open collector, 35V @ 10mA max. high = no fault
2 mA Program Input 0 to 9.00Vdc = 0 to 100% rated output, Zin =10MΩ
3 kV Program Input 0 to 9.00Vdc = 0 to 100% rated output, Zin =10MΩ
4 X-Ray On Lamp Relay Output Common, dry contacts, 30Vdc @ 1A, max
5 X-Ray On Lamp Relay Output Normally open, X-Ray ON = closed
6 mA Monitor Output 0 to 9Vdc = 0 to 100% rated output, Zout =10kΩ
7 X-Ray On Lamp Relay Output Normally closed, X-Ray ON = open
8 kV Monitor Output 0 to 9.00Vdc = 0 to 100% rated output, Zout =10kΩ
9 Signal Ground Ground
10 Signal Ground Ground
11 HV Interlock Return Input Connect to Pin 12 to close HV interlock
12 HV Interlock Output +15Vdc @ open, 5mA when connected to pin 11
13 X-Ray Enable Output +15Vdc @ open, 5mA when connected to pin 15
14 X-Ray Status Output Open collector, 35V @ 10mA max high = X-Ray OFF
15 X-Ray Enable Return Input Connect to pin 13 to enable X-Ray generation

XRB ANALOGINTERFACE— J2 15 PIN MALE D CONNECTOR

Indicator Signal Name Condition Illuminated When...
LED 1 OV High kV occurs
LED 2 UV Low kV occurs
LED 3 UC Low mA occurs
LED 4 OC High mA occurs
LED 5 ARC FLT Arc fault occurs
LED 6 OT Over temperature occurs
LED 7 X-RAY ON X-Rays are enabled
LED 8 PWR Power is ON

表和图

DIMENSIONS: in.[mm]

X-RAY GENERATOR 

FRONT VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 1)

TOP VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 2)

SIDE VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 3)

BOTTOM VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 4)

CONTROL UNIT 

FRONT VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 1a)

TOP VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 2a)

SIDE VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 3a)

BOTTOM VIEW

XRB100 Monoblock® 工业X射线发生器 (Image 4a)

Note: All specifications are subject to change without notice. Please consult the PDF version of this datasheet for the most up-to-date revision.



FAQ

为什么使用油绝缘?
我是否需要确保 MONOBLOCK® 保持冷态?为什么?
我多久需要调校一次 MONOBLOCK® X 射线源?为什么?
AN-12 | 动力X射线管灯丝电路使用电流源的益处